Intrauterine vacuum-induced hemorrhage-control device: A novel approach for PPH Authors Sabahat Hafeez Department of Internal Medicine, Aga Khan University Hospital, Karachi, Pakistan Javeria Saquib Department of Internal Medicine, Dr. Ruth K.M Pfau Civil Hospital, Karachi, Pakistan Farea Ahmed Department of Internal Medicine, Dr. Ruth K.M Pfau Civil Hospital, Karachi, Pakistan https://orcid.org/0000-0002-1367-5790 DOI: https://doi.org/10.47391/JPMA.9602 Abstract Madam, Postpartum haemorrhage (PPH), defined as postpartum blood loss of > 1000 mL, is a life-threatening emergency and the leading cause of maternal mortality accounting for 25% of maternal deaths worldwide (1). PPH can lead to significant morbidity, including shock, ARDS, coagulopathy, infertility due to hysterectomy, and even mortality (4). Uterine atony is the most common cause, accounting for 80% of all cases of PPH (1) (2). Active management of the third stage of labour consisting of a triad of oxytocin, controlled cord traction, and uterine massage can reduce the incidence of PPH by 60% (5). If abnormal uterine bleeding ensues, PPH protocols are activated, including uterine balloon tamponade, uterine packing, uterine artery embolization, or hysterectomy (1, 2). The Jada System (novel intrauterine vacuum-induced haemorrhage-control device) approved by the U.S. FDA in August 2020, utilizes a low-level vacuum to induce negative pressure in the uterine cavity that facilitates uterine contraction to constrict myometrial blood vessels that can help with uterine atony (1). The device is used in patients with PPH where standard PPH treatments have failed or are contraindicated (1). It is a soft medical-grade silicone that attenuates the risk of tissue trauma and can be placed trans-vaginally after 3 cm of cervical dilation after vaginal birth and C-section (1,2). Ultrasound is used to check correct device placement, along with real-time quantification of the expelled blood from the uterine cavity into the graduated canister. The device can be placed for 1.5 hours to 24 hours inside the uterus. The device can be removed after evaluation of evacuated blood and palpation for a firm uterus, both signifying control of the hemorrhage (2). A First-in-Human (FIH) feasibility study conducted in Indonesia on 10 participants with atony-related PPH showed that the device was placed effectively, and bleeding was controlled in under 2 minutes with no unfavorable outcome in any participants (1) (3). The study was conducted with 107 participants of which two-thirds had atony-related PPH with failed medical treatment (1). The Per Protocol showed a 99% success rate in effectively controlling PPH (2). Bleeding halted in a minimum of 3 minutes, the treatment duration was around 3.2 hours and 98% of users regarded it as convenient to use (1). Adverse events included endometritis and vaginal infections all of which were resolved with adequate treatment (2). ---Continue Downloads Full Text Article Published 2023-08-15 How to Cite Hafeez, S., Saquib, J., & Ahmed, F. (2023). Intrauterine vacuum-induced hemorrhage-control device: A novel approach for PPH. Journal of the Pakistan Medical Association, 73(9), 1931–1932. https://doi.org/10.47391/JPMA.9602 More Citation Formats ACM ACS APA ABNT Chicago Harvard IEEE MLA Turabian Vancouver Download Citation Endnote/Zotero/Mendeley (RIS) BibTeX Issue Vol. 73 No. 9 (2023): SEPTEMBER Section LETTER TO THE EDITOR License Copyright (c) 2023 Journal of the Pakistan Medical Association This work is licensed under a Creative Commons Attribution 4.0 International License.