PULSE OXIMETRY

Nasir Khan Jakhrani  ( Department of Anaesthesiology, Jinnah Postgraduate Medical Centre, Karachi. )

Tissue hypoxia is one of the major causes of death in most humans undergoing anaesthesia. Among the causes of tissue hypoxia is a failure of oxygen delivery, which depends on the oxygen supply, lung function and cardiac output. It is directly related to oxygen capacity and affinity of blood which, in turn, depends on the concentra­tion of functioning haemoglobin and its P50. These factors can be compounded by inadequate experience of the anaesthetists1-2. The recent development of pulse oximeters which monitor both the heart rate and provide a continuous measurement of arterial saturation, represents a major advancement in monitoring3. These devices may be placed on the finger, ear lobe or nasal septum and differ from previous oximeters in that they are able to eliminate the background absorption attributable to tissue by measuring the light absorption at two different wavelengths at frequent intervals during each pulse. It is, therefore, possible to derive an ab­solute measure of oxygen saturation without precalibration. The accuracy of pulse oximeters has been evaluated in normal adults4-5 and in patients with cardiorespiratory disease6. In the range of 56-99.5%, all studies found good correlation with arterial blood samples with correlation coeffi­cients(r) of 0.82-0.99. Pulse oximeters are usually unaffected by skin pigmentation but are sensitive to motion artefacts and may give inaccurate results when the pulse volume is reduced by blood loss or severe vasoconstriction due to hypother­mia. They may be affected by the presence of excessive external illumination, bilirubin or ex­traneous dyes in blood or marked venous pulsa­tions7, also by uni and bipolar diathermy due to very high frequency generated by the latter. Pulse oximeters maybe used to advantage as continuous, noninvasive, rapid response monitors of oxygenation in all patients during the immedi­ate pre, intra and postoperative period and in patients in intensive care units who are undergo­ing respiratory therapy or who have significant respiratory or cardiovascular disease. It also acts as a second line monitor of oesophageal intuba­tion and ventilator disconnection. Pulse oximeters present an opportunity for considerable increase in patient safety. An argu­ment can be made for their use in every patient who is unconscious or at risk of sudden arterial desaturation. These instruments are reliable and safe and suffer from no major disadvantages. Unfortunately they are relatively expensive in comparison to most of the equipment used by anaesthetists (but not by other medical specia­lities). They nevertheless represent significant advance in patient monitoring todate as they noninvasively and safely provide a continuous indication of adequate circulatory and respiratory function.

REFERENCES

1. Cooper, J.B., Newbower, R.S. and Kitz, R.J. An analysis of major errors and equipment failures in anaesthesia management; considerations for prevention and detec­tion. Anaesthesiology, 1984; 60: 34.
2. Craig, J. and Wilson, M.E. A survey of anaesthetic misad­ventures. Anaesthesia, 1981; 36: 933.
3. Taylor, M.B. and Whitwam, J.G. The current status of pulse oximetry; clinical value of continuous noninvasive oxygen saturation monitoring. Anaesthesia, 1986; 41:943.
4. Sarnquist, F.H., Todd, C. and Whitcher, C. Accuracy of a new noninvasive oxygen saturation monitor. Anaes­thesiology, 1980; 53: S163.
5. Yelderman, M. and New, W. Jr. Evaluation of pulse oximetry. Anaesthesiology, 1983; 59: 349.
6. Mihrn, F.G. and Halperin, B.D. Noninvasive detection of profound arterial desaturations using a pulse oximetiy device. Anaesthesiology, 1985; 62: 85.
7. Sykes, M.K. Essential monitoring. Br. J. Anaesth., 1987;59:901.

Journal of the Pakistan Medical Association has agreed to receive and publish manuscripts in accordance with the principles of the following committees: