Rapid Diagnostic Modalities for Malaria

Raymond A. Smego  ( Departments of Medicine, The Aga Khan University Medical College, Karachi. )
Jr  ( Departments of Medicine, The Aga Khan University Medical College, Karachi. )
Asim Beg  ( Departments of Microbiology, The Aga Khan University Medical College, Karachi. )

Malaria is a global and resurging infectious disease problem causing approximately three million deaths worldwide each year, mainly iii developing countries. Early diagnosis and prompt drug treatment are essential in order to minimize morbidity and mortality. For decades, microscopic examination of Giemsa-stained peripheral blood smears has been the cornerstone of malaria diagnosis. Thick smears are more useful than thin films when parasitemia is low; once parasites have been detected, thin smears can assist in Plasmodia species identification. Accurate examination of blood films depends upon technical expertise involving proper staining and handling of the slide and microscope, parasite recognition, and practice. Laboratory staff must be well-trained and should undergo refresher courses regularly.
In the search for new diagnostic modalities in malaria, the ideal rapid test should be rapid, simple to perform, easy to interpret, accurate, and inexpensive. Over the past few years there has been tremendous technologic and marketing progress in the development of a number of rapid and specific diagnostic tests to identify patients infected with malaria1-8. As alternatives to conventional stained blood smear examination, these tests hold great promise for use in areas of the developing world where microscopes and/or trained personnel are not readily available, such as in primary health care clinics and other peripheral level facilities. These tests also have potential utility in non-endemic western countries where experience with microscopic malaria detection is limited, and they have also been evaluated for self-use by persons traveling to malaria-prone regions9-11.
Newer, rapid diagnostic malaria tests include polymerase chain reaction (PCR)-based tests, quantitative buffy coat examination, acridine orange immunofluorescent staining, and several immunochromatographic assays. Fluorescent microscopy and nucleic acid detection techniques, however, require skills and equipment which are not universally available in many malaria-endemic countries. Recently introduced immunocapture methods, several of which are now commercially available and which can be performed in about 5 to 10 minutes, are based upon the detection of antigens derived from Plasmodia in lysed peripheral blood, and employ either a dipstick or test strip that have monoclonal antibodies directed against the target parasite antigen1-8. These antigen-capture techniques are easy to run, and interpretation does not require complex equipment or technical support. Thus, they are important breakthroughs in the qualitative detection of malaria parasites.
The ParaSight-F assay (Becton Dickinson, Cockeysville, MD, USA), ICT Malaria Pf assay (ICT Diagnostics, Sydney, Australia), MalaQuick (ICT Diagnostics, Sydney, Australia), PATH falciparum malaria IC strip (Quorum Diagnostics, Vancouver, CA) and Determine Pf test (Abbott Diagnostics, Abbott Park, IL, USA) all detect parasite histidine-rich protein (pHRP-2), a water-soluble protein produced specifically by trophozoites and young gametocytes of Plasmodium falciparum12-19. In field evaluations these test kits have demonstrated comparable or superior detection rates for P. falciparum than conventional microscopy, especially for smear-negative samples12-19. However, die technique may fail to detect P. falciparum infection when blood smears contain only gametocytes, and these qualitative kits are unsuitable for monitoring the response to antimalarial treatment.
Parasite lactate dehydrogenase (pLDH) is an intracellular metabolic enzyme produced by asexual and sexual stages of malaria parasites. Another commercially-available kit, OptiMAL (Flow Inc. Portland, OR, USA), utilizes a dipstick coated with monoclonal antibodies against this enzyme, and can distinguish P. falciparuni from non-P. falciparum species6-9. Differentiation of malarial species is based upon antigenic differences between the pLDH is forms. The enzyme is produced only by live Plasmodium parasites, thus the test has the ability to differentiate live from dead organisms.
In recent years, rapid non-microscopic antigen-capture tests which detect pHRP-2 and pLDH have been extensively studied in field trials in Africa and Asia1,3-9,13-20. By comparing results from these tests with either direct microscopy or PCR, researchers have determined their accuracy and potential advantages. Diagnostic sensitivities and specificities range approximately from 84% to 100% and 89% to 100%, respectively, and positive and negative predictive values between 82% to 100% and 88% to 99%, respec-tively3,5,6,8,10,15-22. The pLDH assay has the utility advantage over pHRP-2 detection in that it provides excellent correlation with traditional blood films in the identification of both P. falciparum and P. vivax malaria3.
Sensitivities of both pHRP-2 and pLDH dipstick tests appear to have direct correlation with parasite density. Lower limits of detection. when false-negative results begin to appear, occur with parasitemia levels that are below 50 to 300 parasites per mL of blood4,6-9,17,19. Rapid dipstick methods may yield positive results when peripheral blood smear staining fails to identify parasites. Such discordant results have been evaluated by re-testing using day 0 and day 1 blood samples, or by using large samples and longer incubation mes19,21. Tests using pHRP-2 detection have shown cross-reactivil of 26% (compared to 3% with a pLDH kit) in blood from patients with detectable rheumatoid factor23. False-positive results may also be explained by persistent antigenemia (occurring in pHRP-2 assays lip to 7 to 14 days after successful treatment, not seen with the pLDH assay) and the possibility of sequestered parasites from incomplete chemotherapy1,4,24. Persistent test positivity after parasite clearance precludes the use of these tests for monitoring early therapeutic responses.
Immunocapture tests have been found useful in other clinical settings including the diagnosis of placental malaria and forensic detection of malaria in postmortem blood specimens22,25. There has also been enthusiasm in considering rapid non-microscopic dipstick tests for use by persons traveling to malaria-endemic regions11,26. Self-interpretation of dipstick tests by travelers has frequently been associated with an unacceptably high incidence of false-negative results despite written instructions before travel; oral instruction appears to enhance performance12,26,27. Accordingly, at the present time the self-use of dipstick tests for malaria diagnosis by travelers cannot be routinely recommended, and these kits should only be prescribed after appropriate instruction and training, and demonstration of successful performance of the test procedure.
In summary, recently introduced rapid. non-microscopic. immunocapture tests can have excellent applicability in malaria diagnosis in settings where microscopes and skilled technicians are not readily available. In general, such tests can be reliably read by field workers without any supervision, and appear to satisfy the desired criteria of being rapid. Easy to perform and interpret and extremely accurate. Making these valuable diagnostic assays affordable and widely available could contribute greatly to controlling the public health impact of this menacing disease.

References

1. Stephens JK. Phanart K, Rooney W. Bamish G. A comparison of three malaria diagnostic tests. Under field conditions in northwest Thailand. Southeast Asian Trop. Med. Puhi Health, 1999;30:625-30.
2. Brenter-Pinchart MR Pinci C Grillot R. Amhroise-Thomas P Diagnosis of malaria in non-endemic Countries Value, limitations and complementarity of existing methods Ann Biol. Clin. 2000:58:310-16.
3. Lee MA. Aw LT. Singh M. A comparison of antigen dipstick assays with polymerase chain reaction (PCR) technique and blood film examination in the rapid diagnosis of malaria Ann Acad. Med..Singapore 1999;28:498-501.
4. Wonsrichanalai C, chuanak N. Tulyayon S. et al Comparison of a rapid field immunochromatographic test to expert microscopy for the detection of Plasmodium falciparum asexual parasitemia in Thailand Acts. Trop 1 999:73 263-73
5. Mishra B. Samantaray JC. Mirdha BR. Evaluation of a rapid antigen capture assay for the diagnosis of falciparum malaria Indian J. Med Res , 1999;109. I 6- 9
6. Ricci L. Viani I. Precolo. et al Evaluation of the Optimal assay teat to detect imported malaria in Italy. New Microbial 2000:23 39 1-8
7. Piper R, Lebras J. Wentworth L, et al. Immunocapture diagnostic assays for malaria using Plasmodium lactate ckhydrogenase (pLDH). Am. J. Trop. Med. Hyg., 1999:60(I): 109.18.
8. Palmer CJ, Lindo IF, Klaskala WI, et al, Evaluation of the Optimal test for rapid diagnosis of Plasmodium vivax and Plasmodium falciparum malaria. J. Clin Microbial., 1998:36 :203-6
9. Cooke AH. Chiodini PL. Doherty T, ct al Comparison of a parasite lactate dehydrogenase-based immunochromatographic antigen detection assay (Optimal) with microscopy for the detection of malaria parasites in human blood samples Am. J. Trop. Med., 1999;60:173-6.
10. Jelinek T. Grobusch HP, Schwcnke S. et al Sensitivity and specificity of dipstick tests for rapid diagnosis of malaria in nonimmune travelers. J. Clin. Microbial., 1999;37.72 1-3.
11. Jelinek T, Grobusch MR Nothdurft UD. Use of dipstick teats for the rapid diagnosis of malaria in nonimmune travelers. J Travel Med., 2000:7175-9.
12. Jelinek T, Amsier L, Grobusch MP, Nothdurit HD Self-use of rapid tests for malaria diagnosis by tourists. Lancet, 1999;354:1609.
13. Tham JM. Lee SH. Tan TM, Ting RC, Kara UA. Detection and species determination of malaria parasites by PCR Comparison with microscopy and with ParaSight-F and lCT malaria Pt’ tests in a clinical environment. J, Olin, Microbinl,. 1999:37:1269-73.
14. Pinto MJ, Pereira NF, Rodrigues S. Kharangate NV, Verenkar MP. Rapid diagnosis of falciparum malaria by detection 01’ Plasmodium falciparum HRP-2 antigen J Assoc. Phys. India, 1999;47:1076-8.
15. Mengesha T, Gebreselassic H. Mohammed U, Assefa T. Woldemichael T. Parasight, F dipstick antigen test in the diagnosis of falciparum malaria in Ethiopia. List Afr. Med. J.. 1999;76:626-9.
16. Bojang KA. The diagnosis of Plasmoduim falciparum infection in Gambian children by field stall using the rapid, manual, ParaSight-F test, Ann Trop. Med. Parasitol.. 1999: 93:685-7.
17. Tjitra E. Suprianto S. Dyer M, Curric BJ, Anstey NM. Field evaluation of the ICT malaria Pf/Pv immunochromatographic test for detection of Plasmodium falciparum and Plasmodium vivax in patients with a presumptive clinical diagnosis of malaria in eastern Indonesia. J. Clin. Microbial., 1999;37:2412-7.
18. Kilian AH. Kahagambe G, Byamukama W, Langi P. Wis P. von Sonnenhurg F Application of the ParaSight-F dipstick test for malaria diagnosis in a district control program. Acta Trop., 1999 ;72:28 1.93.
19. Mills CD, Burgess DC, Taylor HJ, Kain KC. Evaluation of a rapid and inexpensive dipstick assay for the diagnosis of Plasmodium falciparum malaria. Bull World Health Org.. 1999;77:553-9.
20. Singh N. Valecha N. Evaluation of a rapid diagnostic test. Determine malaria pt’, in epidemic-prone, forest villages of central India (Madhya Pradesh). Ann. Trop. Med. Parasitol., 2000;94:421-7.
21. Pieroni P, Mills CD. Ohrt C. Harrington MA, Kain KC. Comparison of the ParaSight-F test and the ICT Malaria Pf test with the polymerase chain reaction for the diagnosis of Plasmodium falciparum malaria in travelers. Trans. R Soc. Trop Med. Hyg., 1998:92:166-9.
22. Sing A, Rauch E, Roggenkamp A, Autenrieth lb. Hcescmann J Evaluation of the ICT malaria Pf test for rapid post-mortem diagnosis of Plasmodium falciparum malaria in corpses examined for forensic reasons. Int. J Legal Med., 20011;11:251-2.
23. lqbal 3. Sher A. Rub A. Plasmodium falciparum histidine-rich protein 2-based immunocapture diagnostic assay for malaria: Cross-reactivity with rheumatoid factors. J Clin. Microbial, 2000;38.11 84-6.
24. Mishra H. Samantary JC. Kumar A. Mirdha BR Study of false positivity of two rapid antigen detection tests for diagnosis of Plasmodium falciparum malaria J clin Microbial.. 1999;37:1233.
25. Leke RF Dyokam KR, Mbu R. Leke RJ. Fogako J, Megnekou R. ct al. Detection of the Plasmodium falciparum antigen histidine-rich protein 2 in blood of pregnant women: Implications for diagnosing placental malaria J. Chin Microbial., 1999:37:2992-6.
26. Funk M. Schlagenhauf P. Tschapp A. Steffen K. MalaQuick versus Parasite F as a diagnostic aid in travelers’ mal aria. Trans. K .Soc Trop. Med. H lyg , 1999;93:268-72.
27. Trachsler H, Schlagenhauf P. Steffen R. Feasibility of a rapid dipstick antigen. Capture assay for self-testing of travelers malaria Trop. Med. Int Health 1999;4:442-7.

Journal of the Pakistan Medical Association has agreed to receive and publish manuscripts in accordance with the principles of the following committees: